1,5-35/6-150 mm2 CES/CNT 150

Tip: CES/CNT 150
Standard: NF C 33-020 | EN 50483-4

NOTE: the product can be delivered with PA shear head nut or AlPA shear head nut
On Customer’s request pa shear head nut can be made in diffrient colour.

CES/CNT 150 is used to achieve contact by simultaneously piercing the insulation on LV ABC conductors of main power distribution line and on LV ABC conductors of street lighting connection line or other small electricity consumer.
Installation wrench: 13; Dismantling wrench: 17 for AlPA shear head nut.
Installation wrench: 17; Dismantling wrench: 22 for PA shear head nut.
Packaging 50 pieces
Connector weight 7,80kg/100 pieces
– MAXIMUM ALLOWED TENSILE FORCE: 12 Nm;
– NOMINAL TENSILE FORCE: 10Nm;
– FORCE AT WHICH FIRST CONTACT IS ESTABLISHED: 4 Nm;
– RANGE OF USE:
Cross section of the main line 6mm2 to 150mm2;
Cross section of the tap-off line 1,5mm2 to 35mm2 ;