Application
Cable of high flexibility grade, used as high voltage insulated conductor from electrical welding machine to electrodes, i.e. as earth connection. Recommended for all low voltage mobile connections. In addition to hand welding, it can be also applied in automobile industry, shipbuilding, transport systems, production lines, tool manufacturing, welding robots. These cables retain their high flexibility also under the influence of ozone, light, oxygen, protective gases, oils and gasoline. Due to their robust construction, they are also resistant to cold, same as to heat and fire. Suitable for outdoor use, but also in dry and damp conditions.
Standards
HD 22.6 S2
DIN VDE 0282 part 6
IEC 60245-6
Construction
Conductor: bare or tinned copper conductor, extra fine wired stranded, class 6 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Separator: polyester foil or paper
Sheath: rubber compound on poly-chloroprene basis (CR) (= Neoprene), i.e. EM5 acc. to DIN VDE 0282 part 803, oil resistant
sheath colour: black
Technical data
Temperature range:
fixed installed: -40 °C up to +80 °C
at usage with bending: -25 °C up to +80 °C
maximal operating temp.: +90 °C
at short circuit of max. 5 s: up to 250 °C
Nominal voltage: 100 V
Test voltage: 1000 V
Maximal tensile strength: 15 N/mm²
Specific el. resistance of insulation: min. 10 MΩ x km
Minimal inner bending radius: 4D
Behaviour in fire: IEC 60332-1
Oil resistance: acc. to DIN VDE 0472 part 803, method A