Application
Light rubber cable, used for easy-duty and medium mechanical loads in dry areas. Suitable for household, kitchens, offices and workshops (for inst. tailoring) for smaller electrical devices (washing-machines, vacuum-cleaners, irons, household appliances, soldering sets etc.) and mobile devices operating in heavier conditions, such as light industrial and agricultural machines. Not suitable for permanent outdoor use. Ozone-resistant, allowed contact with oils and greases.
Standards
HRN HD 22.4 S3
IEC 60245-4
DIN VDE 0282 part 4
Construction
Conductor: bare or tinned copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: rubber compound on ethylene-propylene basis (EPM, earlier: EPR), i.e. EI4 acc. to DIN VDE 0282 part 1
Sheath: rubber compound on ethylene-propylene basis (EPM, earlier: EPR) or on natural and poly- butadiene-styrene rubber basis (NR + PBS, earlier: SBR), i.e. EM3 acc. to DIN VDE 0282 part 1, extruded sheath able to fill up the interstices between the conductors
sheath colour: black
Core colour marking: acc. to HRN HD 308 S2 / VDE 0293-308
Technical data
Temperature range:
during installation: -30 °C up to +60 °C
maximal operating temp.: +60 °C
at short circuit of max. 5 s: up to 200 °C
Nominal voltage: Uο/U = 300/500 V
Test voltage: 2000 V
Maximal operating voltage:
alternating current three-phase and single-phase: Uο/U = 318/550 V
direct current: Uο/U = 413/825 V
Minimal inner bending radius: 7,5D
Behaviour in fire: IEC 60332-1