Application
Power and signal shipboard cable for fixed installation inside the ship acc. to IEC 60092-352 standard. Specially suitable for passenger ships because of improved characteristics under fire. Also applied at open sea platforms.
advantages:
– retained electric function of system within specified time
– halogen-free, no release of toxic and corrosive gases under fire
– reduced smoke manifestation under fire
– no flame propagation in vertical cable bundle, flame retardant
– resistant to oils and greases
– improved mechanical characteristics, resistant to scraping and vibrations
– smaller cable diameter and weight
Standards
IEC 60092-350
IEC 60092-353
Construction
Conductor: bare or tinned copper conductor, multi wire stranded, class 2 acc. to IEC 60228 / HD 383 / DIN VDE 0295, round or sector
Insulation: cross-linked polyethylene – XLPE, acc. to IEC 60092-351 (more recent mark for cross-linked polyethylene: PE-X), concentrically stranded cores, with or without green-yellow protective conductor
Filler: polyolefin based compound: or without filler
Sheath: polyolefin, type SHF1 or SHF2 acc. to IEC 60092-359
sheath colour: black or grey
Technical data
Temperature range:
during installation: -20 °C up to +70 °C
fixed installed: -30 °C up to +80 °C
max. operating temp.: 90 °C (ili 85 °C)
Nominal voltage: Uο/U = 0,6/1 kV
Test voltage: 3,5 kV
Min. inner bending radius:
round conductor, diameter < 25 mm²: 4D
round conductor, diameter > 25 mm²: 6D
sector conductor: 8D
Flame retardant: IEC 60332-1
Flame resistant: IEC 60332-3 kat. A
Halogen-free: IEC 60754-1
Non-corrosive combustion gases: IEC 60754-2
Low smoke density: IEC 61034-2